Generator Model
|
Open Frame Type |
YDG3700EV-6EI |
YDG5500EV-6EI |
| Output |
AC |
Max.. (kW) |
3.7 |
5.5 |
Rated (kW) |
3.5 |
5.0 |
DC |
V-A (W) |
12V-8.3A (100) |
| Rated Voltage |
Volts |
120/240 |
| Rated Current |
Amps |
29.2 / 14.6 |
41.7 / 20.8 |
| Voltage Control System |
With Automatic Voltage Regulator |
| Number of Phases |
Single Phase |
| Type |
Revolving Field, Brush Type AC Generator |
| Excitation System |
Self - Excitation |
| Frequency |
Hertz |
60 |
| Rotation Speed |
Rpm |
3600 |
| Number of Poles |
2 |
| Power Factor |
1.0 |
| Insulation Class |
Class E |
| Bearing Type |
Ball Bearing (Seal Type) |
| Output Receptacle |
AC |
V-A |
125-20 GFCI, 125-30 Twist Lock |
| 125-20 GFCI, 125 / 250-20 Twist Lock |
DC |
250-10 |
| Breaker |
AC |
NFB-16A (Tandem) |
NFB-22A (Tandem) |
DC |
12 Amp Thermal Switch |
| Voltmeter |
V |
120 / 240 |
| Pilot Lamp |
None |
| Grounding Terminal |
1 |
| Revolution |
No Load max. |
3750 + or - 50rpm |
| Speed regulation |
Transient Speed |
% |
Less than or Equal to 10 |
| Speed Drop |
% |
Less than or Equal to 6 |
| Setting Time |
Seconds |
Less than or Equal to 5 |
| Stability |
Frequency Change |
Hz |
Less than, + or - 1 |
| Voltage Regulation |
% |
10 |
| Yanmar Engine Model |
L48V6-GY |
L70V6-GY |
L100V6-GY |
| Engine Type |
1 Cyl, Direct Injected, Air Cooled Diesel |
| Starting System |
Electric Start with Recoil |
| Lowest Starting Temperature (electric) |
Degree F |
Less than or equal to 14 F |
| Protective Device |
Low Oil Pressure Stop Device |
| Capacity |
Fuel Oil |
Quarts |
7.6 |
13.7 |
13.7 |
| Lube Oil |
0.85 |
1.11 |
1.7 |
| Oil Supply Interval |
Fuel Oil |
Hrs |
6.5 |
8 |
5.5 |
| Lube Oil |
58 |
65 |
70 |
| Inclination (continuous) |
Degrees |
Less than or Equal to 10 |